ESCRFTC

Fully Threaded Countersunk Structural Wood Screw

ESCRFTC is a full threaded screw with a countersunk head, suitable for hidden timber to timber assembly and steel to timber assembly. It can also be used for timber reinforcement.

Find it in the Solid Wood Application >

CE-merket
Avtalegrunnlag
Anvendelsesklasse 2
Yellow electro-galvanized steel
Indoor
Solid Wood

Produktinformasjon

Bilder

Egenskaper

Material

  • Hardened carbon steel
  • Electrogalvanized yellow passivated

Advantages

  • Countersunk head: ideal for timber/timber or steel/timber assembly with head flush with surface
  • Underhead ribs: for a clear finish and no timber superficial split
  • Full asymetrical thread for a maximum withdrawal capacity, allows compressive load bearing
  • Half cut point: reduces splitting effect and allows smaller minimum spacings and edge distances. No pre-drilling needed, easier installation when skewed
  • Torx driven: reduces the wear of the bit

Applikasjoner

Suitable for

  • Solid Timber, Glulam timber, CLT, Wood-based panels
  • Pre-drilled steel plate

When to use

  • Timber to timber assembly
  • Steel to timber assembly
  • Timber reinforcement (to transversile tension or compression)

Tekniske data

Dimensjoner

Dimensjoner

Art. nr. Dimensjoner [mm]
l lg d1 d dh Bit Box Quantity
ESCRFTC8.0X1201201105.2815T-4050
ESCRFTC8.0X1401401305.215T-4050
ESCRFTC8.0X1601601505.215T-4050
ESCRFTC8.0X1801801705.215T-4050
ESCRFTC8.0X2002001905.215T-4050
ESCRFTC8.0X2202202105.215T-4050
ESCRFTC8.0X2402402305.215T-4050
ESCRFTC8.0X2602602505.215T-4050
ESCRFTC8.0X2802802705.215T-4050
ESCRFTC8.0X3003002905.215T-4050
ESCRFTC8.0X3503503405.215T-4050
ESCRFTC8.0X4004003905.215T-4050
ESCRFTC10.0X1201201086.11018.5T-5050
ESCRFTC10,0X1601601486.118.5T-50-
ESCRFTC10.0X1801801686.118.5T-5050
ESCRFTC10.0X2002001886.118.5T-5050
ESCRFTC10.0X2202202086.118.5T-5050
ESCRFTC10.0X2402402286.118.5T-5050
ESCRFTC10.0X2602602486.118.5T-5050
ESCRFTC10.0X2802802686.118.5T-5050
ESCRFTC10.0X3003002886.118.5T-5050
ESCRFTC10.0X3503503386.118.5T-5050
ESCRFTC10.0X4004003886.118.5T-5050
ESCRFTC12.0X2002001806.81220T-5025
ESCRFTC12.0X2202202006.820T-5025
ESCRFTC12.0X2402402206.820T-5025
ESCRFTC12.0X2602602406.820T-5025
ESCRFTC12.0X2802802606.820T-5025
ESCRFTC12.0X3003002806.820T-5025
ESCRFTC12.0X3503503306.820T-5025
ESCRFTC12.0X4004003806.820T-5025
ESCRFTC12.0X4504504306.820T-5025
ESCRFTC12.0X5005004806.820T-5025
ESCRFTC12.0X6006005806.820T-5025

Produktkarakteristiske egenskaber

Art. nr. Yield Moment – My,k [Nm] Karakteristisk uttrekks parameter - fax,k,90° [N/mm²] Karakteristisk hovdegjennomtrekningsparameter - fhead,k [N/mm²] Karakteristisk trekkstyrke - ftens,k [kN] Torsional Strength ftor, k [Nm]
ESCRFTC8.020.313.112.424.125.8
ESCRFTC10.036.712.512.24055
ESCRFTC12.048.511.21146.773

Montering

Montering

Spacing and Edge distances - Shear loaded screws

Art. nr. Minimum edge distances and spacing for shear loaded screws [mm]
Angle between load and grain = 0° Angle between load and grain = 90°
a1.0 a2.0 a3.t.0 a3.c.0 a4.t.0 a4.c.0 a1.90 a2.90 a3.t.90 a3.c.90 a4.t.90 a4.c.90
ESCRFTC8.0403280322424323280563224
ESCRFTC10.0504080403030404080704030
ESCRFTC12.0604884483636484884844836

a1 and a2 can be multiplied by 0.85 for panel/timber assembly, and by 0.7 for steel/timber assembly.

Spacing and edge distances - Axially loaded screws

Art. nr. Minimum edge distances and spacing for axially loaded screws [mm]
a1 a2 a3.c a4.c
ESCRFTC8.040404032
ESCRFTC10.050505040
ESCRFTC12.060606048

Abacus

Timber toTimber characteristic capacities

Art. nr. Product characteristic capacities - Timber to Timber C24
Axial resistance Shear resistance parallel to the grain depending of t1 [Rv.0.k] [kN] Shear resistance perpendicular to the grain depending of t1 [Rv.90.k] [kN]
t1 [mm] Rax.k [kN] 35 [mm] 40 [mm] 45 [mm] 60 [mm] 75 [mm] 80 [mm] ≥100 [mm] 35 [mm] 40 [mm] 45 [mm] 60 [mm] 75 [mm] 80 [mm] ≥100 [mm]
ESCRFTC8.0X22011010.485.785.995.995.995.995.995.994.655.035.335.45.45.45.4
ESCRFTC8.0X24012011.536.056.256.256.256.256.256.254.655.035.435.565.565.565.56
ESCRFTC8.0X26013012.586.316.516.516.516.516.516.514.655.035.435.565.565.565.56
ESCRFTC8.0X28014013.626.336.746.746.746.746.746.744.655.035.435.565.565.565.56
ESCRFTC8.0X30015014.676.336.746.746.746.746.746.744.655.035.435.565.565.565.56
ESCRFTC8.0X35017517.296.336.746.746.746.746.746.744.655.035.435.565.565.565.56
ESCRFTC8.0X400----------------
ESCRFTC10.0X24012013.38-7.878.238.358.358.358.35-6.596.857.437.437.437.43
ESCRFTC10.0X26013014.63-8.188.548.668.668.668.66-6.597.027.747.747.747.74
ESCRFTC10.0X28014015.88-8.498.858.988.988.988.98-6.597.028.068.068.068.06
ESCRFTC10.0X30015017.13-8.89.169.299.299.299.29-6.597.028.188.188.188.18
ESCRFTC10.0X35017520.25-9.059.7710.0110.0110.0110.01-6.597.028.188.188.188.18
ESCRFTC10.0X40020021.13-9.059.7710.0110.0110.0110.01-6.597.028.188.188.188.18
ESCRFTC12.0X28014015.46-----10.110.1-----8.98.9
ESCRFTC12.0X30015016.8-----10.4410.44-----9.249.24
ESCRFTC12.0X35017520.16-----11.2811.28-----10.0810.08
ESCRFTC12.0X40020023.52-----12.1212.12-----10.0810.08
ESCRFTC12.0X450----------------
ESCRFTC12.0X50025030.24-----12.4712.47-----10.0810.08

These capacities are valid for:

  • Timber element under the head with thickness ≤ t1 disclosed in adjacent column
  • Screw axis between 45° and 90° from timber grain for ESCR(XXX), and 90° from timber grain for all other screws.

For tightening screws (partially threaded), t1 dimension is the maximum thickness of the under-head timber member for which the thread is fully in the pointside timber member, for an optimum installation and tightening.

The shear capacities are given for several timber thicknesses t1 of the under-head member under the following configurations:

  • Load axis at 0° from both timber grains Rv.0°.k
  • Load axis at 90° from both timber grains Rv.90°.k

These capacities are valid for C24 timber grades or higher
The pre-drilled hypothesis for capacity and distances calculation is fulfilled.
For partial threaded screws, capacities are only given for configurations where the thread is less than 5mm in under-head timber member, in order to achieve optimum installation and tightening.
Clause (2) in 8.3.1.2 from EN1995-1-1:2004+A2:2014 about embedment length is ignored in these calculations.

Steel to Timber characteristic capacities

Art. nr. Product characteristic capacities - Steel to Timber C24
Axial resistance [Rax.st.k] [kN] Shear resistance - Thin plate Shear Resistance - Thick steel
Rv.0.st.k [kN] Rv.90.st.k [kN] Rv.0.st.k [kN] Rv.90.st.k [kN]
ESCRFTC8.0X180-----
ESCRFTC8.0X200-----
ESCRFTC8.0X22022.016.745.569.537.86
ESCRFTC8.0X24024.16.745.569.537.86
ESCRFTC8.0X26024.16.745.569.537.86
ESCRFTC8.0X28024.16.745.569.537.86
ESCRFTC8.0X30024.16.745.569.537.86
ESCRFTC8.0X35024.16.745.569.537.86
ESCRFTC8.0X400-----
ESCRFTC10.0X24028.510.018.1814.1611.56
ESCRFTC10.0X2603110.018.1814.1611.56
ESCRFTC10.0X28033.510.018.1814.1611.56
ESCRFTC10.0X3003610.018.1814.1611.56
ESCRFTC10.0X3504010.018.1814.1611.56
ESCRFTC10.0X4004010.018.1814.1611.56
ESCRFTC12.0X28034.9412.4710.0817.5514.26
ESCRFTC12.0X30037.6312.4710.0817.6414.26
ESCRFTC12.0X35044.3512.4710.0817.6414.26
ESCRFTC12.0X40046.712.4710.0817.6414.26
ESCRFTC12.0X450-----
ESCRFTC12.0X50046.712.4710.0817.6414.26

Shear capacities are given for thick (tst = d) and thin (tst = 0,5xd) steel plates under the following configurations:

  • Load axis at 0° from timber grain Rv.0°.k
  • Load axis at 90° from timber grain Rv.90°.k

These capacities are valid for C24 timber grades or higher.
For intermediate steel thicknesses, capacities shall be calculated by linear interpolation between the limiting thin and thick plate values.
The pre-drilled hypothesis for capacity and distances calculation is fulfilled.

Timber to timber - Cross pair of screws

Art. nr. Crossed pair of screws - characteristic capacities
Header Joist Installation distance Characteristic capacities (Pull-out / Buckling) Rv.pair = min(Rw.k.pair ; Rbuck.k.pair) [kN]
hj min [mm] 1 pair 2 pairs m [mm] mi [mm] 1 pair 2 pairs
bj min [mm] bj min 2 [mm] Rw.k.pair [kN] Rbuck.k.pair [kN] Rw.k.pair [kN] Rbuck.k.pair [kN]
ESCRFTC8.0X2208816884124828714.827.41 + 13.99 /kmod27.6613.82 + 26.11 /kmod
ESCRFTC8.0X2409518284124899416.38.15 + 13.99 /kmod30.4215.21 + 26.11 /kmod
ESCRFTC8.0X260102196841249610117.798.89 + 13.99 /kmod33.1916.59 + 26.11 /kmod
ESCRFTC8.0X2801092108412410310819.279.63 + 13.99 /kmod35.9517.97 + 26.11 /kmod
ESCRFTC8.0X3001172258412411111620.7510.37 + 13.99 /kmod38.7219.35 + 26.11 /kmod
ESCRFTC8.0X3501342608412412813324.4512.22 + 13.99 /kmod45.6322.81 + 26.11 /kmod
ESCRFTC8.0X400----------
ESCRFTC10.0X24095182105155899418.929.45 + 19.62 /kmod35.317.64 + 36.62 /kmod
ESCRFTC10.0X2601021961051559610120.6810.34 + 19.62 /kmod38.619.29 + 36.62 /kmod
ESCRFTC10.0X28010921010515510310822.4511.22 + 19.62 /kmod41.8920.94 + 36.62 /kmod
ESCRFTC10.0X30011722510515511111624.2212.1 + 19.62 /kmod45.1922.59 + 36.62 /kmod
ESCRFTC10.0X35013426010515512813328.6414.31 + 19.62 /kmod53.4426.72 + 36.62 /kmod
ESCRFTC10.0X40015229510515514615129.8814.93 + 19.62 /kmod55.7527.87 + 36.62 /kmod
ESCRFTC12.0X260----------
ESCRFTC12.0X28010921012618610310821.8610.92 + 24.81 /kmod40.7920.39 + 46.29 /kmod
ESCRFTC12.0X30011722512618611111623.7611.87 + 24.81 /kmod44.3422.16 + 46.29 /kmod
ESCRFTC12.0X35013426012618612813328.5114.25 + 24.81 /kmod53.226.6 + 46.29 /kmod
ESCRFTC12.0X40015229512618614615133.2616.63 + 24.81 /kmod62.0731.03 + 46.29 /kmod
ESCRFTC12.0X450----------
ESCRFTC12.0X50018736612618618118642.7721.38 + 24.81 /kmod79.839.9 + 46.29 /kmod

Sertifiseringer

Ytelses Erklæring (DoP)

European Technical Assessment (ETA)

eta-13-0796.pdf (4.21 MB)

Nedlastinger

  • Flyer Solid-Drive

    Flyer Solid-Drive

    Solid-Drive skruer gjør jobbene til ingeniører og byggherrer enklere. Designet for høy ytelse øker de tillatte belastningene, samtidig som monteringen går raskere – reduserer arbeids- og materialkostnadene.

  • Structural Fasteners Technical Guide

    Structural Fasteners Technical Guide

    I denne tekniske katalogen finner du generell informasjon, karakteristiske parametere samt lastekapasiteter for C24 massiv tre, GL24h limtre, CLT, stål til tre og plater til tre, for vårt Solid-Drive utvalg av konstruksjonsskruer.

CAD og BIM bibliotek

2D
3D

Buy from Distributor

No items available.

Contact

Simpson Strong-Tie Norge

Simpson Strong-Tie c/o Christiania Spigerverk

Org.nr: 9672 09 562
Smalvollveien 58
0667 Oslo
Norge